Hitachi screw type chiller accessories high pressure
switchG7D06955F

Main features
The main types of pressure switches include the open type and the
closed type. The main features are:
1, adopts the imperial pipe thread fast joint or copper pipe welded
installation structure, installation is flexible, easy to use, no
need for special installation fixed.
2, insert wire type connectors can be freely selected by the user.
3, sealed stainless steel sensors are safe and reliable.
The pressure range can be manufactured according to the pressure
value arbitrarily selected by the user.
A pressure switch is a device combined with an electrical switch.
When a pre-set fluid pressure is reached, the contact is switched
on and off. It is mainly used in the output of alarm or control
signals on industrial equipment such as power plants,
petrochemicals, and metallurgical industries. It has important uses
in the industrial field and can prevent damage to important devices
in production projects and avoid major production accidents.
2. Pressure switch main sensitive element 2.1 bellows
Features: Durability and vibration resistance are better than those
of Borden tubes, and the range of connection difference can be
adjusted. The main materials are stainless steel, phosphorus
bronze, etc.. The price is relatively high, but the measurable
pressure range is small, with a maximum of 40 MPa(CB33) 2.2
diaphragm.
Features: Excellent corrosion resistance, the main materials are
NBR, fluorine rubber, etc., such as CS, CL series use such
sensitive components. Pressure switch quick and easy automatic
selection included.
Folding edit this paragraph for use
Pressure switches are mechanical and electronic.
Pressure switch
Pressure switch
G& The L electronic pressure switch is a high-precision
instrument amplifier that amplifies the pressure signal, collects
and processes data through high-speed MCU, and compensates with
built-in precision sensors. It is a high-precision device that
detects pressure and liquid level signals and realizes pressure and
liquid level monitoring and control. It is widely used in automated
systems for measuring gas and liquid pressure such as chemical,
mechanical, hydrological, electric, and environmental protection.
Because the adjustment is easy and flexible, the installation is
simple and can replace most situations where liquid level switches
are used.
1, the product core adopts a new type of intelligent
microprocessing chip, functional and practical performance is
stable.
2, LED shows the current pressure or liquid level value;
3, pressure or liquid level can be set to start or stop according
to their own needs;
4, 4 LED products three units can be selected according to customer
needs: Mpa, KG.F/CM2, PSI
5, you can set the high and low pressure or liquid level alarm
point, and output to the control device through relay or optical
coupling; Output of dual-circuit relay(single knife double throw)
switch quantity;
6, two relays / two optical couples/bands 4-20 mA / 0-10V output
can be selected;
7, the use of high-precision pressure sensors, higher precision
than the mechanical pressure switch, small delay, fast response,
stable and reliable; To adjust the dead-free zone, relay action
pressure points can be set arbitrarily in the entire range of
measurement;
8, the use of keys to adjust the action pressure, easy to use, more
flexible; Protection Level: IP65, which can be used in harsh
environments;
Folding Technical Parameters
Range range: -100 Kpa ~ 200 MPa;
Power supply voltage: 12 ~ 35 V DC(24 V DC calibration voltage) /
AC 220vAC power supply
Output relay capacity: 380V 3A, 220V 5A, 24V DC 5A, etc..
Precision: Better than 0.0.5 % FS, 1 % FS, etc..
Setting range: full program segment can be set
Sampling rate: 10 times per second(the required speed can be
customized according to customer needs).
Interface threads: M20 * 1.5, G1/4, G1/2, 1/4 NPT(customized to
customer needs)
Folding operation instructions
Digital pressure switch is an intelligent control instrument that
integrates pressure measurement, display, and control. It has the
characteristics of simple operation, good vibration resistance,
high control accuracy, and long service life.
Practice Note Take the MD-S910 smart pressure switch as an example:
Pressure switch
Pressure switch
1. Pressure Display Window
2. MPa unit indicator light
3. Kg/cm unit indicator light
4. PSI unit indicator light
5. Run indicator light
6. Lower indicator light
7. Ceiling indicator
8. Power indicator
9. (ON / OFF) Run Key
10. Digital Minus Key(<UNK>)
11. Digital Add Key(<UNK>)
12. Set SET Key
13. Pressure Installation Port
Folding Settings
Key Definition Description
1. (ON/OFF) Run key: System Run key, parameter setting must close
the run key, otherwise the setting can not be performed.
2. (SET) Set key: Press this button to enter the upper and lower
pressure setting state, and press 3 seconds to enter the system
setting state.
3. Add key(<UNK>): The number of buttons is increased by 0.01
MP at a time, and the number is increased by 0.1 MPa after 2
seconds.
4. Minus key(<UNK>): The number of buttons is reduced by 0.01
MP at a time, and the number is reduced by 0.1 MPa after 2 seconds.
Folding edit this paragraph operation method
1. Set a way to control pressure
(1) Press the(ON / OFF) running key, turn off the running
indicator, and the pressure control system is closed.
(2) Establishment of upper / lower control limits
Press the SET key once and enter the lower limit setting
state(corresponding to the lower limit indicator light). Set the
value by(<UNK>)(<UNK>). After the lower limit is set,
press the SET key to enter the upper limit setting. The setting
method is the same.
(3) After the setting is completed, press the ET key to
automatically store the setting value on the computer chip(after
the parameter is modified, no key operation will automatically save
the current parameter setting within 5 seconds).
(4) Press the(ON / OFF) running key again(the corresponding running
indicator light is on) and the motor begins to work.
2. Unit switching method: Short press(ON/OFF) running key, turn off
running indicator light, short press increase key(<UNK>) can
switch units between MPa, Kg/cm, PSI. Turn on the running indicator
when setting is complete.
3. Zero position zero function: Short press(ON/OFF) run key, turn
off running indicator light, long press reduce key(<UNK>) 5
seconds can zero the current pressure value, correct zero position
error. Turn on the running indicator when setting is complete.
(When using this function, pressure switches must not exert
pressure. )
System Function Mode
Press the SET key for 3 seconds to enter the system settings, and
then press the SET key to display the following function patterns.
After all functional mode settings are completed, press(ON / OFF)
to run the setting value automatically into the computer chip.
Function Mode
Function Details
Use
Setting Method
Boot check
R001/R000
Close / Open
Function opening: The relay stays closed for 1 minute after boot,
and the relay continues to open even if the pressure exceeds the
upper limit setting value.
To prevent the motor from being started, the pressure in the tube
changes instantaneously, causing the motor to start frequently.
After entering the system settings, the function is turned on or
off by adding keys(<UNK>) / reducing keys(<UNK>), and
the underscore is indicated as the default function.
Automatic pressure check
S000/S001
Turn On / Off
Functional opening: After the relay is closed, the controller can
not detect pressure changes for 3 minutes and will automatically
disconnect the relay and alert the "E-1" on the screen.
Avoid water drain, pipe leakage pressure and other causes the
measured pressure for a long time to reach the upper limit,
resulting in the motor idling.
After entering the system settings, the function is turned on or
off by adding keys(<UNK>) / reducing keys(<UNK>).
Overpressure self-examination
N001/N000
Close / Open
Function turn on: When the pressure is greater than(upper limit +
0.1 MPa), disconnect the relay, the screen alarm shows "E-2", when
the pressure is back below(upper limit + 0.1 MPa), the alarm is
cancelled, and the controller resumes work.
Remind the customer control system that there is pressure beyond
the control limit. Please check if the system is abnormal.
After entering the system settings, the function is turned on or
off by adding keys(<UNK>) / reducing keys(<UNK>).
Control Delay
H001/H000 Close / Open
Function Open: When the pressure reaches the action point, the
controller does not immediately move, delays the action, and delays
the time of the action.
Setting the control delay can prevent the pressure in the tube from
being unstable, and the guidance call will be frequently started
and the motor will be damaged.
After switching H001 to H000, press the SET key to display "0010".
Change this value by the(<UNK>)(<UNK>) key in seconds.
The default is 10 seconds. Press the SET key to save the setting
and jump out.
Parameter protection
P001/P000
Close / Open
Function open: Press any key other than the(ON / OFF) run key, the
screen will display "--", at this time you need to enter a password
to set the upper and lower limits and other parameters.
The parameters set by the protection engineer are not modified.
When "--" is displayed, the password is entered through
the(<UNK>) key, the SET key is shifted, and the password is
"1111". After short confirmation by the SET key, the parameter
setting can be performed. When the system reruns, it automatically
enters